Optional fields use std::optional.
Fields
| Field | Type | Description |
|---|
value | T | Current business data |
sequence | std::uint64_t | SDK sequence number, monotonically increasing within the same data category |
source_time | std::optional<double> | Data source time |
observed_at | double | Monotonic milliseconds since SDK creation |
source_time is optional producer time in milliseconds: SDK-generated Glove time follows Unix milliseconds or the reference set by sync_time(), while explicit external input uses the caller’s clock domain. observed_at is monotonic milliseconds since SDK creation, not Unix time.
Fields
| Field | Type | Description |
|---|
source | std::string | Source ID that produced the data |
timestamp | double | Data timestamp |
sequence | std::optional<std::uint64_t> | Sequence number provided by the device or data source |
frame_id | std::optional<std::string> | Frame identifier provided by the device or data source |
Fields
| Field | Type and description |
|---|
position | std::array<double, 3>, 3D position |
quaternion_xyzw | std::array<double, 4>, XYZW quaternion |
Fields
| Field | Type and description |
|---|
thumb, index, middle, ring, pinky | GloveNodePose, fingertip poses of the five fingers |
timestamp_ms | std::optional<double>, preferred optional millisecond input; when omitted, the current shared time reference is used; see Timestamps & external time sync for the time semantics |
timestamp_sec | std::optional<double>, deprecated compatibility input; multiplied by 1000 and mutually exclusive with timestamp_ms |
| Field | Type | Description |
|---|
fingertips | std::map<GloveFinger, GloveNodePose> | Fingertip poses in metres and XYZW |
glove_id | std::string | Glove data identifier |
hand_side | Side | Hand side |
finger_names | std::vector<GloveFinger> | Current finger order |
raw_valid_mask | std::map<GloveFinger, bool> | Raw-data validity per finger |
held_mask | std::map<GloveFinger, bool> | Whether each finger retains its previous valid value |
quality_flags | std::vector<std::string> | Hand quality flags |
coordinate_frame | std::string | Physical glove: device_hand; external hand input: external_hand |
fresh | bool | Whether the component updated in this snapshot; latest() does not consume this flag |
timestamp_ms | double | Component time in milliseconds |
received_monotonic_ms | double | Monotonic receipt time in milliseconds |
session | std::optional<std::uint64_t> | Optional device session identifier |
sync | std::optional<std::uint32_t> | Optional synchronization identifier |
pair_sequence | std::optional<std::uint32_t> | Optional pair sequence |
et | std::optional<GloveHelixEmfTime> | Optional device event-time information |
| Field | Type | Description |
|---|
position | std::optional<std::array<double, 3>> | Optional position in metres |
quaternion_xyzw | std::optional<std::array<double, 4>> | Optional XYZW quaternion |
valid | bool | Whether the wrist observation is valid; invalid coordinates are absent |
flags | std::uint32_t | Device status flags |
errors | std::uint32_t | Device error flags |
quality | std::optional<double> | Optional quality value |
coordinate_frame | std::string | device_wrist |
fresh | bool | Whether the component updated in this snapshot; latest() does not consume this flag |
timestamp_ms | double | Component time in milliseconds |
received_monotonic_ms | double | Monotonic receipt time in milliseconds |
session | std::optional<std::uint64_t> | Optional device session identifier |
sync | std::optional<std::uint32_t> | Optional synchronization identifier |
pair_sequence | std::optional<std::uint32_t> | Optional pair sequence |
et | std::optional<GloveHelixEmfTime> | Optional device event-time information |
| Field / method | Type | Description |
|---|
v | std::uint8_t | Event-time format version |
clock | std::string | Device clock identifier |
span | std::array<std::uint32_t, 2> | Device-reported range values, preserved as reported |
ref() | double | Recommended reference time accessor in fractional device-clock milliseconds |
error() | std::optional<double> | Recommended optional timing error accessor in milliseconds (empty means unknown) |
b_error() | std::optional<double> | Recommended optional basis timing error accessor in milliseconds (0.0 is a valid zero) |
basis | std::string | Device-reported time basis |
filtered | std::uint8_t | Device-reported filtering marker |
sample_hz | std::uint32_t | Sample rate in Hz |
hdr_g | std::array<std::array<std::uint32_t, 2>, 6> | Device-reported 6 × 2 metadata |
ref_us | std::uint32_t | Reference time in microseconds (marked @deprecated; use ref()) |
error_us | std::optional<std::uint32_t> | Optional time error in microseconds (marked @deprecated; use error()) |
b_error_us | std::optional<std::uint32_t> | Optional basis-time error in microseconds (marked @deprecated; use b_error()) |
ref_ms() / error_ms() / b_error_ms() | double / std::optional<double> | Deprecated millisecond accessor aliases (marked [[deprecated]]; use ref() / error() / b_error()) |
| Field | Type | Description |
|---|
hand | std::optional<GloveHandPose> | Optional hand component |
wrist | std::optional<GloveWristPose> | Optional independent wrist component |
| Field | Type | Description |
|---|
meta | TelemetryMeta | Source, time and frame identifiers |
payload | GlovePosePayload | Hand and wrist components |
quality | std::map<std::string, Value> | Extensible quality information |
| Field | Type | Description |
|---|
gyroscope_raw | std::array<std::int16_t, 3> | Three-axis raw gyroscope counts |
accelerometer_raw | std::array<std::int16_t, 3> | Three-axis raw accelerometer counts |
| Field | Type | Description |
|---|
gyro_mdps | std::optional<std::array<std::int32_t, 3>> | Optional three-axis angular velocity in thousandths of a degree/second |
accel_mg | std::optional<std::array<std::int32_t, 3>> | Optional three-axis acceleration in thousandths of g |
std::variant<GloveImuRawCounts, GloveImuPhysicalValues>
| Field | Type | Description |
|---|
id | std::uint8_t | Sensor identifier, not an array position |
location | GloveImuLocation | Sensor location; unknown when not identified |
valid | bool | Whether this sensor observation is valid |
fresh | bool | Update flag in this snapshot; latest() does not consume it |
flags | std::optional<std::uint32_t> | Optional device status flags |
age_ms | std::optional<std::uint16_t> | Optional data age in milliseconds |
values | GloveImuValues | Raw counts or physical values; check the type first |
| Field | Type | Description |
|---|
valid | bool | Whether the observation is valid |
x | std::optional<std::int32_t> | Optional X-axis raw count; valid zero is retained |
y | std::optional<std::int32_t> | Optional Y-axis raw count |
z | std::optional<std::int32_t> | Optional Z-axis raw count |
units | std::string | raw_counts |
unknown / board / thumb_tip / index_tip / middle_tip / ring_tip / pinky_tip / thumb_back / index_back / middle_back / ring_back / pinky_back / wrist
| Field | Type | Description |
|---|
imus | std::vector<GloveImuSample> | Sensor observations selected by id and location |
magnetometer | std::optional<GloveMagnetometer> | Optional magnetometer observation |
session | std::optional<std::uint64_t> | Optional device session identifier |
packet_sequence | std::optional<std::uint32_t> | Optional packet sequence |
sync | std::optional<std::uint32_t> | Optional synchronization identifier |
device_ts_ms | std::optional<std::uint32_t> | Optional device time in milliseconds |
new_mask | std::optional<std::uint16_t> | Optional sensor-update mask |
| Field | Type | Description |
|---|
channel_id | std::uint8_t | EMF channel identifier. |
li | std::array<std::array<std::int64_t, 3>, 3> | Low-frequency I signed integral matrix, 3 × 3. |
lq | std::array<std::array<std::int64_t, 3>, 3> | Low-frequency Q signed integral matrix, 3 × 3. |
hi | std::array<std::array<std::int64_t, 3>, 3> | High-frequency I signed integral matrix, 3 × 3. |
hq | std::array<std::array<std::int64_t, 3>, 3> | High-frequency Q signed integral matrix, 3 × 3. |
samples | std::optional<std::uint32_t> | Optional sample count. |
low_used_mask | std::optional<std::uint16_t> | Optional low-frequency usage mask. |
invalid_mask | std::optional<std::uint16_t> | Optional invalid-value mask. |
| Field | Type | Description |
|---|
units | std::string | demodulated_integral, demodulated integrals. |
session | std::uint64_t | Device session identifier when available. |
sync | std::optional<std::uint32_t> | Device synchronization identifier when available. |
frame_sequence | std::optional<std::uint32_t> | Frame sequence corresponding to the hand pair_sequence. |
et | std::optional<GloveHelixEmfTime> | Optional device EMF event timing. |
dropped | std::optional<std::uint32_t> | Optional dropped-frame count. |
channels | std::vector<GloveEmfChannel> | Raw integral matrices for each EMF channel. |
| Field | Type | Description |
|---|
meta | TelemetryMeta | Source, time and frame identifiers. |
payload | GloveEmfPayload | Typed channel content. |
quality | std::map<std::string, Value> | Device quality information, preserving missing values. |
| Field | Type | Description |
|---|
meta | TelemetryMeta | Source, time and frame identifiers |
payload | GloveImuPayload | Per-sensor IMU and optional magnetometer |
quality | std::map<std::string, Value> | Extensible quality information |
GlovePressure returns readings and estimated_kpa in matching 460-point order. kPa estimates use an average palm curve, with raw values 107–255 sharing an approximately 40.01 kPa software ceiling. Frames without pressure produce no new sample.
| Field | Type | Description |
|---|
readings | std::array<std::uint8_t, 460> | 460 raw readings from 0 to 255 in device order. |
estimated_kpa | std::array<double, 460> | 460 kPa estimates in matching point order, using an average palm curve. |